How to Clear M35160WT using VVDI Multi Prog?
One customer asked how to clear M35160WT using VVDI Multi Prog. He input 0000 to upper 2 line then write but still the same not clear both upper line, I tried many time.
Here is the Answer:
The option "M35160(ST)" doesn't support ERASE.
For other options, "Erase INC" button will erase the front 2 lines. After erasing INC operation, then select ALL or MEMORY option to read data for verify, Reading data the front 2 lines should be all "00", manually enter the targert mileage, then click "Write" option, operation completed.
Done! Hope this could help!
http://blog.xhorsevvdi.com/how-to-clear-m35160wt-using-vvdi-multi-prog/