Question:

Condor Mini Plus II, The machine was working fine for a few weeks after placing mother board. It has broken probe and cutter because it brakes when machine doesn’t wanna go up. Maybe Z axis motor idk.

Solved Condor Mini Plus Ii Motor Measurement Broke Probe And Cutter 1

Solved Condor Mini Plus Ii Motor Measurement Broke Probe And Cutter 2

Solved Condor Mini Plus Ii Motor Measurement Broke Probe And Cutter 3

Motor Measurement Results:

Solved Condor Mini Plus Ii Motor Measurement Broke Probe And Cutter 4

Solved Condor Mini Plus Ii Motor Measurement Broke Probe And Cutter 5

Solved Condor Mini Plus Ii Motor Measurement Broke Probe And Cutter 6

Solved Condor Mini Plus Ii Motor Measurement Broke Probe And Cutter 7

Here is the

Reason:

Wrong connections of Y-axis and Z-axis cables.

 

Solution:

Reverse Y-axis and Z-axis cable.